Analytical equipments
eli | Louvain-la-Neuve
Main equipment
The main equipment of the platform are listed below, with the applications for which they are used.
Equipment | Principle | Applications |
|---|---|---|
δ18O and δD Analyzer ![]() | The Picarro L2130-i analyser is an essential tool for research requiring highly accurate and reliable isotopic analysis of water (δD and δ18O). | Isotope analysis of water |
C,N,S Elemental Analyser system ![]() | The elementary analyzer works on the principle of catalytic combustion and separation of the gases released during it. | Food |
Isotope Ratio Mass Spectrometer - IRMS ![]() | Coupled with an elementary analyser, the Elementar Isoprime precisION determines the isotopic signatures of solid matrices (soil, sediments, plants, etc.). | Isotopic signature of solid matrices (soil, sediments, plants, etc.) |
Gas Chromatography ![]() | Gas Chromatography is a technique for separating a mixture of thermostable and volatile molecules. | Determination of : |
High Pressure Liquid Chromatography ![]() | High Pressure Liquid Chromatography allows the separation or the purification of one or more compounds of a mixture with a view to their identification and their quantification. | • Determination of : |
Inductively Coupled Plasma spectrometry ![]() | Inductively Coupled Plasma spectrometry (ICP) is a chemical analytical method allowing the determination of almost all the elements simultaneously thanks to the high temperature of the argon plasma (> 8000°C). | Mineral matrices |
Liquid Phase Ion Chromatography ![]() | Liquid Phase Ion Chromatography (IC) allows the identification and simultaneous quantification of various inorganic and organic ions (cations and anions). The principle of this technique is based on the differences in ion affinities for a functionalized substrate (ion exchange resin) in the presence of a carrier liquid phase (eluent). | Environment |
TOC Analyser ![]() | The determination of dissolved carbon is an essential analytical prerequisite in many agronomic and environmental problems in aqueous media: detection of organic contaminants in soils, control of the decomposition of organic matter from the soil surface, etc. | - in the clay fraction (f <2 µm) of soils and in sediments |
UV-VIS Spectrometer ![]() | Spectrophotometry is a non-destructive and rapid analysis method which is widely used in the laboratory. This technique makes it possible to determine the absorbance of a chemical substance in solution, that is to say its capacity to absorb the light passing through it. | This technique will also make it possible to follow the kinetics of a chemical reaction. |
X-Ray Diffractometer ![]() | The application of X-Ray Diffraction (DRX) relates to the identification and quantification of crystalline minerals in the soil. Among these, phyllosilicates constitute a privileged object of study given their preferential location in the fine fraction of soils and their colloidal properties: high specific surface, electrical charge, ion exchange, adsorption of metallic elements, pesticides, etc. | - Mineralogical identification of soils (Quartz, Mica, Magnetite, Pyroxene…) |
Various specialized equipment



Chemical Oxygen Demand COD Analyzer
• The second method concerns solids and will also be used if more precision is required compared to the kit.
For a COD of solids or more precise, a conventional method is used based on the Belgian standard "NBN T 91-201 - Water analysis".
The materials which can be oxidized under the conditions of the test are oxidized in an acid medium (concentrated sulfuric acid H2SO4) by an excess of potassium dichromate solution K2Cr2O7 in the presence of mercury sulphate which forms a complex with the chlorides (allowing them to be trapped and avoiding interference) and the catalyst, silver sulphate.
A reflux heating step is carried out for 30 minutes (15 minutes for liquids). The excess potassium dichromate is titrated with a solution of iron and ammonium sulphate (Mohr salt) in the presence of an indicator, iron orthophenanthroline (ferroin).
The oxidation is more extensive than that obtained with potassium permanganate (see NBN T91-202) although all the organic materials are not completely oxidized.
Mineral reducers (ferrous iron, sulphides, sulphites, nitrites ...) being also oxidized, can interfere.
The result is expressed in milligrams of oxygen consumed per liter (mg_DCO/L) for liquids or in grams of oxygen consumed per grams of material (g_DCO/g) for solids.
Electrical conductivity meter
• The principle consists in measuring the resistance of a solution located between two electrodes; plates covered with platinum black face to face and supplied by an alternating voltage. Once the cell is immersed in the ionic solution, the voltage across its terminals is varied and the intensity of the current flowing through it is measured.
• Depending on the concentration of ions present, the solution will have a greater or lesser conductivity. Before making a measurement, the conductivity meter must be calibrated which consists of determining the cell constant using standard solutions (usually a KCl solution).
• Tables provide information on the conductivity of the ions and that of the standard solution as a function of the temperature which has a strong influence on the measurement.
• The conductivity meter is based on Ohm's law: U = R*I where U represents the voltage (volts), I the intensity (amps) and R the resistance (ohms). It then gives a value of the conductance G, expressed in siemens, knowing that: G = 1/R.
• The conductivity depends on the concentration of the ions, the nature of the ionic solution and the temperature of the solution.
Kjeldahl distillation system
• The first step is the mineralization of organic nitrogen to obtain its ammonium salt form. The acid pH allows the ammonium salt to be in its protonated form NH4+. The nitrogenous organic matter degrades in the presence of a catalyst (copper sulphate and potassium sulphate) and by attack of concentrated sulfuric acid at high temperature. Carbon is eliminated in the form of carbon dioxide (CO2), hydrogen in the form of water (H2O) and nitrogen remains in the form of ammonium ion NH4+.
• After digestion in concentrated sulfuric acid comes the second step which is the distillation of ammonium. Adding excess sodium hydroxide alkalizes the medium, making it possible to pass from ammonium sulfate to ammonia gas. This is entrained by the distillation water steam and is condensed on contact with a condenser.
• In the last step, the titration, the ammonia collected in a solution of boric acid H3BO3 (ammonia trap) forms ammonium borate which is titrated with standardized sulfuric acid in the presence of a colored indicator. This titration is said to be indirect.
The Kjeldahl method is a universal, precise and reproducible technique.
MWAE: MicroWave-Assisted Extraction - UltraWAVE
pH meter
• The bulb of the measuring electrode is made of porous glass or a permeable glass membrane covered with silica and metal salts. There are two silver threads covered with silver chloride; one which is immersed in a pH 7 buffer in the bulb and the second is immersed in the saturated solution of potassium chloride in the reference electrode.
• When the probe is placed in a solution to be analyzed, the hydrogen ions accumulate around the bulb and replace the metal ions of the latter. This ion exchange generates an electrical flow which is captured by the silver wire. The voltage of this electrical flow is measured by comparison with the voltage generated with the reference electrode and is converted into a pH value by the pH meter. The porosity of the glass membrane decreases with its continuous use, thus the performance of the probe.
• Increasing the acidity of the solution and therefore the concentration of hydrogen ions relative to the internal solution of the electrode increases the voltage, which has the consequence of lowering the pH value. It will be the opposite in an alkaline medium because the voltage will decrease and cause the pH value to increase.
• The pH meter is calibrated before each first measurement with two buffer solutions (either pH 7 and 4 in an acid medium, or pH 7 and 10 in a basic medium). It is important to calibrate at the same temperature as that of the analysis solution otherwise there would be an impact on the accuracy of the measurements.
• This device measures a global potential or voltage which is based on the ratio between the concentration of H3O+ ions and the difference in electrochemical potential which is established in the glass electrode. The reference electrode provides a stable voltage since it has a fixed concentration of potassium chloride solution. While the potential of the measuring electrode only depends on the pH of the solution to be analyzed. It is the difference in potential (voltage) generated by the ion exchange through the glass membrane of the measuring electrode and the reference electrode which is measured by the pH meter.
Soxhlet extractor
The finely ground sample is placed in a thick rod-shaped filter paper cartridge and placed in an extraction chamber. This fine grinding before extraction increases the solid-liquid contact area, which helps to shift the transfer equilibrium towards the solvent.
The solvent then continues to evaporate, while the extracted substances remain in the distillation flask and concentrate as the extraction takes place, but it is imperative that their boiling temperature is significantly higher than that of the extracting solvent.
A disadvantage of this hot method is that it can degrade heat-sensitive chemicals and you cannot work cold with this system.
Applications
• Extraction of polycyclic aromatic hydrocarbons (PAHs) from polluted soils
• Extraction of polychlorinated biphenyls (PCB) from polluted soils
SPE - Solid Phase Extraction
Solid Phase Extraction generally requires four steps.
• First, the cartridge is packaged by percolating a certain volume of solvent (or more) in order to activate the support. The cartridge must imperatively remain wet before depositing the sample.
• Second, the sample is loaded onto the cartridge and its percolation begins, allowing the separation of analytes and interferents. The targeted compounds adsorb on the cartridge.
• Third, the cartridge is washed to remove the interferents by passing a suitable eluent leaving the analytes adsorbed.
• Finally, the analytes are collected by elution with an appropriate solvent.
! Note that it is possible that the interferents adsorb on the cartridge allowing the purification of the analytes. The desorption step would therefore not be encountered in this specific case since the analytes will pass directly through the stationary phase without adsorption.
It is useful during the development of the extraction to check each washing and elution step by chromatography to avoid any loss and contamination.
A wide range of cartridges exists and the platform performs Solid Phase Extractions in normal phase, reverse phase, cation exchanger as well as the anion exchanger.
X-Ray Fluorescence (XRF) spectrometer